Sunny Tripower 10000TL |
Sunny Tripower 12000TL |
Sunny Tripower 15000TL |
Sunny Tripower 17000TL |
|
Input (DC) |
|
|
|
|
|
Max. DC power (@ cos φ = 1) |
10200 W |
12250 W |
15340 W |
17410 W |
|
Max. DC voltage |
1000 V |
1000 V |
1000 V |
1000 V |
|
MPP voltage range |
320 V – 800 V |
380 V – 800 V |
360 V – 800 V |
400 V – 800 V |
|
DC nominal voltage |
600 V |
600 V |
600 V |
600V |
|
Min. DC voltage / start voltage |
150 V / 188 V |
150 V / 188 V |
150 V / 188 V |
150 V / 188 V |
|
Max. input current / per string |
A: 22 A, B: 11 A / 33 A |
A: 22 A, B: 11 A / 33 A |
A: 33 A, B: 11 A / 33 A |
A: 33 A, B: 11 A / 33 A |
|
Number of MPP trackers / strings per MPP tracker |
2 / A: 4, B: 1 |
2 / A: 4, B: 1 |
2 / A: 5, B: 1 |
2 / A: 5, B: 1 |
|
Output (AC) |
|
|
|
|
|
AC nominal power (@ 230 V, 50 Hz) |
10000 W |
12000 W |
15000 W |
17000 W |
|
Max. AC apparent power |
10000 VA |
12000 VA |
15000 VA |
17000 VA |
|
Nominal AC voltage; range |
3 / N / PE, 230 V / 400 V; 160 V – 280 V |
3 / N / PE, 230 V / 400 V; 160 V – 280 V |
3 / N / PE, 230 V / 400 V; 160 V – 280 V |
3 / N / PE, 230 V / 400 V; 160 V – 280 V |
|
AC grid frequency; range |
50, 60 Hz; –6 Hz, +5 Hz |
50, 60 Hz; –6 Hz, +5 Hz |
50, 60 Hz; –6 Hz, +5 Hz |
50, 60 Hz; –6 Hz, +5 Hz |
|
Max. output current |
16 A |
19.2 A |
24 A |
24.6 A |
|
Power factor (cos φ) |
0.8 leading ... 0.8 lagging |
0.8 leading ... 0.8 lagging |
0.8 leading ... 0.8 lagging |
0.8 leading ... 0.8 lagging |
|
Phase conductors / connection phases / power balancing |
3 / 3 /— |
3 / 3 /— |
3 / 3 /— |
3 / 3 /— |
|
|
|
|
|
|
|
Efficiency |
|
|
|
|
|
Max. efficiency / Euro-eta |
98.1 % / 97.7 % |
98.1 % / 97.7 % |
98.1 % / 97.7 % |
98.1 % / 97.7 % |
|
|
|
|
|
|
|
Protection devices |
|
|
|
|
|
DC reverse-polarity protection / reverse current protection |
yes /electronic |
yes /electronic |
yes /electronic |
yes /electronic |
|
ESS switch-disconnector |
yes |
yes |
yes |
yes |
|
AC short circuit protection |
yes |
yes |
yes |
yes |
|
Ground fault monitoring |
yes |
yes |
yes |
yes |
|
Grid monitoring (SMA Grid Guard) |
yes |
yes |
yes |
yes |
|
Galvanically isolated / all-pole sensitive fault current monitoring unit |
—/ yes |
—/ yes |
—/ yes |
—/ yes |
|
DC overvoltage protector type II |
opt. |
opt. |
opt. |
opt. |
|
String failure detection |
yes |
yes |
yes |
yes |
|
Protection class / overvoltage category |
I / III |
I / III |
I / III |
I / III |
|
General data |
|
|
|
|
|
Dimensions (W / H / D) in mm |
665 / 690 / 265 |
665 / 690 / 265 |
665 / 690 / 265 |
665 / 690 / 265 |
|
Weight |
65 kg |
65 kg |
65 kg |
65 kg |
|
Operating temperature range |
–25 °C ... +60 °C |
–25 °C ... +60 °C |
–25 °C ... +60 °C |
–25 °C ... +60 °C |
|
Noise emission (typical) |
www.SMA-Solar.com |
www.SMA-Solar.com |
www.SMA-Solar.com |
www.SMA-Solar.com |
|
Internal consumption: (night) |
1 W |
1 W |
1 W |
1 W |
|
Topology |
transformerless |
transformerless |
transformerless |
transformerless |
|
Cooling concept |
OptiCool |
OptiCool |
OptiCool |
OptiCool |
|
Electronics protection rating / connection area (as per IEC 60529) |
IP65 / IP54 |
IP65 / IP54 |
IP65 / IP54 |
IP65 / IP54 |
|
Climatic category (per IEC 60721-3-4) |
4K4H |
4K4H |
4K4H |
4K4H |
|
Features |
|
|
|
|
|
DC connection: SUNCLIX |
yes |
yes |
yes |
yes |
|
AC connection: screw terminal / spring-type terminal |
—/ yes |
—/ yes |
—/ yes |
—/ yes |
|
Display: text line / graphic |
—/ yes |
—/ yes |
—/ yes |
—/ yes |
|
Interfaces: RS485 / Bluetooth |
opt. / yes |
opt. / yes |
opt. / yes |
opt. / yes |
|
Warranty: 5 / 10 / 15 / 20 / 25 years |
yes / opt. / opt. / opt. / opt. |
yes / opt. / opt. / opt. / opt. |
yes / opt. / opt. / opt. / opt. |
yes / opt. / opt. / opt. / opt. |